To comply with part l of the building regulations 2010 all roofs to rooms except those in unheated buildings should be thermally insulated to a maximum u value of of 0 18 w m k.
Warm flat roof insulation regulations.
If 180mm is to be installed then 100mm board might be introduced between the rafters there has to be a minimum 25mm air gap between the insulation and the underside of the tiles or slates with an 80mm board running across the rafters.
Flat roofs there are two common forms of construction for flat roofs.
For guidance on roof insulation please contact us on 44 01257 488 000.
There should be no insulation below the deck and no ventilation is required.
Warm deck roof with this type of roof the insulation is placed above the roof deck but below the weatherproofing.
Insulation can also help to limit condensation and contribute to acoustic insulation depending on the type of insulation used.
Inverted warm deck roof.
The definition of a flat roof according to bs 6229 is having a pitch less than 10 o to the horizontal however some in the industry would consider up to 15 o as their definition of a flat roof.
As you can see below there are separate regulations for england wales and scotland.
Take our online course on the building regulations and standards.
The insulation is placed below the waterproof covering and is either mechanically fixed or bitumen bonded on to the top of the deck.
Insulating the roof the cold roof method means you place the insulation between the joists with ventilation above the roof insulation.
Find warm flat roof cold flat roof insulation solutions at iko polymeric.
The sandwich warm deck roof is the most common type of flat roof.
Cold roofs have the waterproof layer placed directly onto the roof deck and the insulation inside the roof just above the ceiling.
Warm deck the type of insulation for this is usually of a rigid type and the thickness will vary depending on the manufacturer s specifications.
Cold deck this is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
Cold roofs and warm roofs.
When building a flat roof it is vital that a degree of falls is built into the construction to ensure rainwater run off.
Warm roof construction is considered to be much more efficient and is an easier build.
Insulating a flat roof using the warm roof construction method means you place the roof insulation over the timber decking.
Below that there are more detailed guides to the thermal insulation parts of building regulations standards.
Warm deck sandwich or cold deck.
There are two types of flat roof.
In this case ventilation is required and the roof can still become wet with condensation which may cause materials to decay.
Others would treat even steeper pitches as flat roofs.
The insulation boards in an inverted warm deck are laid over the structural deck and the waterproof covering.